Cement Resistor
Home  >  Products  >  Resistor  >  More Resistors  >  Cement Resistor
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
DESCRIPTION
http://www.youtube.com/channel/UCZ3mV8GmGNcX4WcYEoWX-_g/featured


Cement resistance standard book (Rx27-1- 7w- 6k8-J type)

size:

Size (mm)

One

B

C

d

Φd

value

10±1

9±1

35±1

85±2

0.68±0.05

Rated value:

style

RX27-1

rated power

7 watts

Derating curve

Rated voltage

Maximum voltage

500V

Maximum overload voltage

700V

tolerance

Joule (±5%)

Resistance range

6K8

range of working temperature

-55℃〜+ 155℃

For more information about cement resistors, please download the PDF file named "Standard Style Manual for Cement Resistance" above.
Performance
http://www.youtube.com/channel/UCZ3mV8GmGNcX4WcYEoWX-_g/featured


description

Performance requirements

testing method


Resistance temperature
coefficient


TCR≤350ppm/℃


Test temperature
+ 20℃/ -55℃/ + 20℃/ + 125℃/ + 20℃


Short-term overload

  • Relative error ≤ (1% relative error ±0.05R)

No visible damage, clearly marked

2.5 times rated voltage or maximum overload voltage (lower limit) for 5 seconds

Wiith fixed voltage

No flashover or malfunction

AC 700V for 1 minute

Terminal strength

Pull


△ R≤ ± (1 % R + 0.05R)
No obvious damage


Φd0.68mm; load 20N 10s

Winding


Φd0.68mm; load 20N 900

Twisted

3600 instead

Anti-vibration


△R≤±(1%+ 0.05R)
No obvious damage


3 directions, 2 hours each

Solder heat resistance


△ R≤ ± (1 % R + 0.05R)
Clear marks, no visible damage


350℃ 2mm from the body, 3 seconds

Solderability

At least 95% of the immersed surface must be covered with new solder and no defect buildup.


235℃
2 mm from the body for 2 seconds


Temperature cycle


△ R≤ ± (1 % R + 0.05R)
No obvious damage



-25 / + 155℃
5 cycles


humidity


△ R≤ ± (5 % R + 0.05R)
No obvious damage



40℃95%RH
1344 hours



70℃
Load life



△R≤±(5%R + 0.1R)
No obvious damage, clearly visible


Rated voltage or maximum voltage 1.5 hours open for 0.5 hours close 70 degrees Celsius for 1000 hours


For more information about cement resistors, please download the PDF file named "Standard Style Manual for Cement Resistance" above.

CONTACT US